E.6
Replace of the v-belt for the internal cooling water pump
The relative high ambient temperature in the closed sound insulated capsule (about 85°C) can be
a reason for a reduced lifespan of the v-belts. It is possible that the "softener" in the rubber com-
pound lose their effect after a short operating time because the air in the sound insulated capsule
can be relative warm and dry. The v-belt must be controlled at very short time intervals. It may be
required to change the v-belt after several weeks because of unfavourable conditions. Therefore,
control should be carried out after an interval of 150 operating hours. The v-belt is a wearing part.
There should be enough spare v-belts on board. We recommend that you have the respective
manual within reach.
1. Loosen the screw on the deflection
pulley bracket
Fig. E.6-1: Screw above the alternator
2. Loosen the screw beneath the alterna-
tor
Fig. E.6-2: Screw beneath the alternator