GENERATOR MUST BE SHUT OFF IMMEDIATELY IF:
Cause
Solution
- motor rpm suddenly rises or drops
- unusual noise comes from genset
- exhaust colour suddenly becomes dark
- motor overheats
- oil pressure drops, oil light suddenly flashes
Refer to respective section of manual and if necessary,
have repaired by Kubota-Service, or Panda represen-
tative.
F.2
Technical data
F.2.1 Technical data generator
Generator
Panda 6000i PMS
Generator type
PM-Synchronous Generator
Winding type
AGT
Wiring mode
3~
Protection mode
IP 44
Insulation class
H
Nominal voltage
2x300 V
Frequency
373 Hz
Nominal speed
-> 2800 rpm
Max. current
2x5,7 A
Apparent power
6,0 kVA
Real power
6,0 kW
Power factor
1,0
Table 1: Technical data generator