Intelligent stepless automatic controller for DC-fan
RE0201_V1_UserDoc_r10_eng.fm
Kapitel/Chapter A: Intelligent stepless automatic controller for DC-fan - Seite/Page 113
Fischer Panda Datenblatt/Datasheet
A.1.5 12V / 24V - Operation
For 12V and/or 24V-operation the pre-resistor for the operating voltage of control electronics must be adapted.
This pre-resistor consists of two resistances, which are connected in series. For 12V-operation one of these resi-
stances is short circuit with the solder joint J102. For 24V-Betrieb the solder joint J102 must be opened. Additio-
nally different safety devices (fuses) must be installed depending upon operating voltage.
Main fuse (flat fuse on the printed circuit board):
12V-operation: 50A flat fuse
24V-operation: 30A flat fuse
Output fuse (plug fuse onthe terminal block, each two pieces):
12V-operation: 25A plug fuse
24V-operation: 20A plug fuse
A.2 Technical Data
Characteristics
closed current (electronics off)
0,5mA
closed current (electronics on)
10 - 15mA
Benchmark figure of the temperature control:
fan start-up
60°C - 80°C
max. number of revolution
65°C - 100°C
tolerance of the temperatures
± 5%
Maximum ratings
maximum ambient temperature (for operation)
50°C
Maximum ratings: Battetry operation 12V
nominal load operating voltage (continuity)
11 VDC - 14.4 VDC
load operating voltage (15min)
- 16.0 VDC
maximum idle speed operating voltage (3 sec)
17 VDC
nominal load current (continuity)
40 A
maximum load current (3 sec)
44 A
nominal valtage fan
12 VDC
Maximum ratings: Battery operation 24V
Summary of Contents for AGT 6000 PVMV-N
Page 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Page 6: ......
Page 10: ...8 Socket wrench set Hexagon wrench keys ...
Page 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Page 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Page 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Page 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...