10
Safety Precautions
The electrical Installations may only be carried out be trained and
tested personnel!
The generator may not be taken into use with the cover removed.
The rotating parts (belt-pulley, belts, etc) must be so covered and protected do that there is no danger to life and
body!
If a sound insulation covering must be produced at the place of installation, then well-placed signs must show that
the generator can only be switched on with a closed capsule.
All servicing-, maintenance or repair work may only carried out, when the motor is not running.
Electrical voltages above 48 volts ( battery chargers greater than 36 volts) are always dangerous to life). The rules of
the respective regional authority must be adhered to. Only an electrician may carry out installation of the electrical
connections for safety reasons.
General safety references for the enterprise of a AGT generator.
With all energized systems, with which the current is more than 50 Ampère, special safety precautions must be
made, in order to protect the environment of the components against fire.
It is to be ensured absolutely that at the battery a main switch in well accessible place is accommodated, so that with
danger of the main switches can be separated immediately. The main switch must be however also directly at the
battery installed. If this place is not well accessible, a power relay must be used instead of the main switch which can
be served manually, which can be served then if necessary from different places. The switches for the power relay
are to mark accordingly as main switches DC battery "with danger switch off!".
Cooling of the rectifier block at the marine versions
The retifier block is cooled with fresh water. A normal cooling of the rectifier block is therefore only possible, as long
as the cooling water supply of the generator functions duly. The cooling water supply of the generator must be so fur-
nished therefore that by a wide dirt deflector it is guaranteed that from outside no dirt can be sucked in into the line
system. If this is not attainable, the supply must be secured by a flow switch or a negative pressure switch. The gene-
rator must be switched off, if the cooling water supply is impair.
The temperature safety device on the rectifier block can be regarded only as additional safety device. The tempera-
ture rise at the diods is so fast that the rectifiers can be damaged during a unique interruption of the cooling water
supply. A safe protection from damage of the rectifiers is not possible by the temperature monitoring on the rectifier
radiator box. Thus this can take place only by means of an appropriate external monitoring of the cooling system.
ATTENTION!
Do not connect the minus pole of the starter battery to the ground of the boat because of galvanic reason.
Warning!
Never start the generator with the battery disconnected, the rectifiers will be damaged!
CAUTION!
Contact of the electrical contacts may be DANGER TO LIVE!
Summary of Contents for AGT 6000 PVMV-N
Page 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Page 6: ......
Page 10: ...8 Socket wrench set Hexagon wrench keys ...
Page 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Page 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Page 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Page 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...