Remote Control Panda 6-50
Seite/Page 118 - Kapitel/Chapter A: Remote Control Panda 6-50
F1WT1-95E730 Panda 6-50 Fernbedienpanel_eng.fm
Fischer Panda Datasheet
A.1 Cleaning and replacement of parts at the generator
The battery must always be disconnected, if work on the generator or electrical system is
to be carried out, so that the generator cannot be unintentionally started.
Note the safety instruction in the generator manual.
The raw water valve must be shut (marine version).
Attention!!! Parts of the generator and the cooling water may be hot after operation
!!!DANGER!!!
A.2 General information
The Panda generator is supplied with an external remote control panel. The remote control panel is necessary to
control the generator and to evaluate the motor/generator properties. Generator control includes, on switch, pre-
heat, starting and stopping generator functions.
The remote control panel is equipped with some new monitoring functions, which increase the operational safety
of the generator. A failure message is shown over contacts which are normally closed. If a connection is intermit-
ted, a failure message is triggered.
The generator may not be run without the remote control panel.
Fig. A.2-1: Remote Control Panel
01
02
03
04
05
08
09
10
11
15
12
13
14
06
07
01. Warning light for cooling water temperature
02. Warning light for water leak (sensor optional)
03. Warning light for AC fault (optional)
04. AC voltage control light
05. Warning light for winding temperature
06. Warning light for oil pressure
07. Battery charge voltage 12 V - DC control lamp
08. LED display for pre-glow
09. Pre-glow button (Heat)
10. Generator „START“-button
11. Control light for Generator-Start
12. Generator „Off“ button
13. Generator „On“ button
14. Generator „stand by“ control light
15. Running hours counter
Summary of Contents for AGT 6000 PVMV-N
Page 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Page 6: ......
Page 10: ...8 Socket wrench set Hexagon wrench keys ...
Page 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Page 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Page 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Page 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...