Intelligent stepless automatic controller for DC-fan
Seite/Page 112 - Kapitel/Chapter A: Intelligent stepless automatic controller for DC-fan
RE0201_V1_UserDoc_r10_eng.fm
Fischer Panda Datenblatt/Datasheet
T
A.1.3 Function of the clamps for the Master-Slave-Operation
Clamp 11+12:
Control input for slave operation. Clamp 11 is the positive input. Clamp 12 is the negative
input. The input is floating, so that via this input connected fan controllers of the same source
can be supplied, without a ground loop develops.
Clamp 13+14:
Output for the master-slave-operation. At clamp 13 is the signal and at clamp 14 is ground.
A.1.4 Remote controlled switching on and off of the fan controller
he fan controller can be switched on and/or off over the connection "ON" (clamp 9). If at connection "ON" lies the
same voltage as at the connection "BAT +", the fan controller is switched on. If at connection "ON" lies no voltage,
the fan controller is switched off. If this option is not needed, then the connection "ON" can connected directly on
the printed circuit board, over the solder joint J101, with the connection "BAT +".
• J101 closed: Fan control Lüfterregler always on
• J101 open: Fan control only on if operation voltage at connection "ON"
The solder joint J101 is seen from the direct line clamp directly behind the main safety device (main fuse) on the
printed circuit board.
Summary of Contents for AGT 6000 PVMV-N
Page 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Page 6: ......
Page 10: ...8 Socket wrench set Hexagon wrench keys ...
Page 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Page 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Page 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Page 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...