Remote Control Panda 6-50
F1WT1-95E730 Panda 6-50 Fernbedienpanel_eng.fm
Kapitel/ChapterA: Remote Control Panda 6-50 - Seite/Page 121
Fischer Panda Datasheet
A.3.3
Starting Generator
1. If necessary, open the fuel valve.
2. If necessary, close the main battery switch.
3. Check if all the load has been switched off.
The load is switched off, before the generator is switched off. The generator is not to be started with load connected. If necessary, the
main switch or fuse should be switched off or the load should be individually switched off.
4. Press „ON“ button.
NOTE: If the red control light for oil pressure illuminates if the panel is switched on, this is an sign that the panel has an error. In this
case the generator can not stop automatically if there is a disturbance.
Control light for "ON" Button must light up.
5. Pre-heat engine.
Pre-heating is necessary for every running temperature. Pre-heating is not necessary, only if the generator has just been run. The hea-
ting period should take at least 6 seconds, however, 20 seconds at the maximum. Heating must last for 20 seconds at a temperature of
+5°C. If a second attempt is to be made, then a pause of at least 60 seconds is required.
The generator can be started with the assistance of a pre-heating device at temperatures as low as - 20°C. Please note that the gene-
rator can only be run at temperatures below -8°C with winter fuel and additional special additives.
6. Press „START“ button.
The electric starter may only be used for a maximum of 20 seconds. Thereafter, a pause of, at least, 60 seconds is required. If the gen-
set does not immediately start, then the fuel intake should be checked to ensure it is flowing freely. (For temperatures below - 8°C
check whether there is winter fuel)
7. Check circuit-voltmeter, to test whether there is AC-voltage and is within the tolerance rage (Frequency and
voltage).
The AC voltage should be within a tolerance of ± 3 Volt without load at the nominal voltage. When running without load, the generator
frequency should be 4% below the nominal voltage. The generator should be checked, before the load is switched on, if the current
remain at this level.
8. Switch on load.
The load should only be switched on if the generator voltage is within the permissible range. Parallel connection of several load should
be avoided, especially if there are load with electric motors, such as air-conditioning units in the system. In this case, the load must be
connected Step by Step.
Summary of Contents for AGT 6000 PVMV-N
Page 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Page 6: ......
Page 10: ...8 Socket wrench set Hexagon wrench keys ...
Page 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Page 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Page 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Page 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...