The Panda Generator
AGT 6000 PVMV-N 12V_24V - Chapter A: The Panda Generator Page 39
A.4 Operating instructions
A.4.1 Preliminary remark
Pre-heating the diesel motor
The motor must be pre-heated, if the diesel motor is designed as a "pre-combustion chamber
motor" for indirect fuel injection. A quick glow fitting is used for all Kubota-diesel motors. This glow
fitting may only be used for a maximum of 20 seconds without a pause. A pre-glow period of 5 - 6
seconds suffices for ambient temperatures above 20°C (plus). For lower temperatures the
preglow period should be increased.
Tips regarding Starter Battery
Fischer Panda recommends normal starter battery use. If an aggregate is required for extreme
winter conditions, then the starter battery capacity should be doubled. It is recommended that the
starter battery be regularly charged by a suitable battery-charging device (i.e., at least every 2
Months). A correctly charged starter battery is necessary for low temperatures.