Appendix
Page 94 AGT 6000 PVMV-N 12V_24V - Chapter E: Appendix
E.3
Troubleshooting
GENERATOR OUTPUT VOLTAGE TOO LOW
If the generator delivers less than 80V current ("undervoltage"), there can be various reasons for this:
Cause
Solution
Generator is overloaded.
Reduce the electrical load. (Switch off consumers)
Motor is not reaching the rated rpm.
Refer to "motor faults" section.
Actuator is not in maximum position.
Check actuator resp. renew.
VCS-voltage controler defective or wrong adjusted.
Check resp. renew.
GENERATOR VOLTAGE TOO HIGH (MORE THAN 80V)
The following reasons may be the cause, if the generator delivers more than 80V ("overvoltage"):
Cause
Solution
The engine is running at the wrong speed.
Check the speed of the motor with a rev or frequency
counter, set the correct speed.
VCS-voltage controler defective or wrong adjusted.
Check resp. renew.
Actuator defective.
Check resp. renew.
GENERATOR VOLTAGE FLUCTUATES
Cause
Solution
1. Fault or defect on the consumer side.
2. A motor fault.
1. Check if the power requirement of the consumer
fluctuates.
2. See "Motor running irregularly".
MOTOR DOES NOT TURN OVER WHEN STARTING
Cause
Solution
Battery main switch is switched off.
Check the position of the battery main switch, if neces-
sary switch on..
Battery voltage not sufficient.
Check that connection is firm and whether corrosion
has occurred..
Starting current fault.
The voltage of full batteries fall to a maximum of 11V.
The wiring is severed if the voltage does not drop. The
battery is discharged if the voltage drops further.
Summary of Contents for AGT 6000 PVMV-N
Page 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Page 6: ......
Page 10: ...8 Socket wrench set Hexagon wrench keys ...
Page 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Page 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Page 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Page 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...