3.3 Diagnosis via INTERBUS
The CP system makes available the following
diagnostic options via the INTERBUS:
– Entries in the diagnostic status register of the
module.
3.3.1 Diagnostic status register
The diagnostic register of the module is structured spe-
cifically for the INTERBUS and contains the following
diagnostic information:
n
n + 1
7
0
7 6 5 4 3 2 1 0
USER User fault parametrizing
PF
Periphery fault, e.g. valve terminal
BUS
Bus fault
CTRL
Fault in module/hardware
DETECT
Diagnostic routine is active
RUN
Diagnostic transmission is active
ACTIVE
Selected configuration is ready to run
READY
Module is ready to run
Fig. 3/3: Structure of the diagnostic status register
The CP system triggers "PF Periphery fault" as a com-
mon error message.