Assign each slave with a logical INPUT
and OUTPUT address.
Example:
configuration list with ID code and process data
channel bits:
String assignment
CP system
ID
code
Process data
channel bits
I/O address (IN/OUT)
String 0:
16 outputs and
16 electrical inputs
3
48
O 20.0 ... 21.7
I 20.0 ... 21.7
String 1:
reserved
O 22.0 ... 23.7
I 22.0 ... 23.7
String 2:
16 outputs and
16 electrical inputs
O 24.0 ... 25.7
I 24.0 ... 25.7
String 3:
non-reserved
Address range can be used
for other bus slaves
2. Commissioning
2-14
CP FB6-E 9809c