Connecting the continuing installation remote bus
Continuing
installation
remote bus
Pin no.
Designation
Meaning
1
DO
Data out
2
/DO
Data out inverse
3
DI
Data in
4
/DI
Data in inverse
5
Earth/GND
Reference conductor
6
FE
Functional earthing of
installation remote bus
7
+ 24 V
Supply to
installation remote bus
8
+ 0 V
Supply to
installation remote bus
9
RBST
Create bridge to
pin 5
Sleeve
Screening
Screening/shielding
Plug selection
Part no.
9-pin plug with socket insert,
screened/shielded with sleeve/housing.
Possible designs:
a) straight socket
b) angled socket
c) angled socket (locking)
a) RC-09 P 1 N 128 049
b) RC-09 P 1 N 12T 049
c) RC-09 P 3 N 12T 0Z0
Cable selection
LIYCY 3x2x0.25 mm
2
+ 3 x 1 mm
2
IBS INBC METER/S (resistant to welding)
28 59 87 0
9
8
7
6
5
4
3
2
1
1. Installation
CP FB6-E 9809c
1-15
Summary of Contents for Compact Performance CP-FB6-E
Page 1: ...Compact Performance CP fieldbus node 6 Programming and diagnosis Fieldbus protocol INTERBUS...
Page 11: ...Contents and general safety instructions X CP FB6 E 9809c...
Page 12: ...Chapter 1 Installation 1 Installation CP FB6 E 9809c 1 1...
Page 29: ...1 Installation 1 18 CP FB6 E 9809c...
Page 30: ...Chapter 2 Commissioning 2 Commissioning CP FB6 E 9809c 2 1...
Page 58: ...Chapter 3 Diagnosis 3 Diagnosis CP FB6 E 9809c 3 1...
Page 70: ...Appendix A Technical appendix A Technical appendix CP FB6 E 9808c A 1...