The following dialogue window will then appear:
Fig. 2/2: Dialogue window "Insert Device"
Enter the following in the dialogue fields:
•
ID Code
Always enter Ident-code 3 for a CP system (with in-
puts and outputs).
•
Process Data Channel
Enter here the number of inputs and/or outputs
on your CP system. The last used string is decisive
here (see CP system manual).
CP system last
used string
Equipment on CP
system (assigned
address range)
Process data
channel bits
0
Up to 16 inputs/outputs
1)
16
1
Up to 32 inputs/outputs
1)
32
2
Up to 48 inputs/outputs
1)
48
3
Up to 64 inputs/outputs
1)
64
1)
Valves and/or electrical outputs
•
Device Type:
The default entry "Remote bus device" can be ente-
red.
•
Save these entries with OK.
2. Commissioning
CP FB6-E 9809c
2-7