If you use the controllers of another manufacturer as
master on the INTERBUS, you can set the process
data word to suit your addressing. To do this, set DIL
switch element 4 to
ON = Standard mode (controller
manufacturer other than Siemens). The high byte (byte
n+1) and the low byte (byte n) will then be swapped.
CAUTION
•
When replacing a CP field bus node CP-FB6-E,
make sure that the DIL switch is correctly set.
You thereby avoid errors in addressing the inputs/out-
puts.
Standard mode: structure of process data word
High byte (byte n+1)
Low byte (byte n)
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
DIL switch element 4: ON = Standard mode (manufacturer other than Siemens)
Fig. 2/3: Structure of process data word in Standard mode with
manufacturers other than Siemens
4
1
2. Commissioning
CP FB6-E 9809c
2-23