Possible entries:
•
Profile Number
The Festo CP system complies with the INTERBUS
I/O profile 12
H
. Enter this value in the box "Profile
Number."
•
Interface Type
The default entry "Interface Universal” can be trans-
ferred. Alternatively you can select the
types
Remote bus or Installation remote bus.
•
Icon
Open the dialogue window "Icon ...,”, if you wish to
use specific icons for the Festo CP system.
PLEASE NOTE
The specific icons for the Festo valve terminals can
be found on the accompanying CD-ROM.
•
If necessary, read the file "Readme.txt" on the
CD-ROM, in order to obtain a brief summary of the
contents of the CD-ROM.
•
Copy the file "Festo.ICL" into the CMD directory
\PICTURE\.
2. Commissioning
CP FB6-E 9809c
2-9