XL-4, XL-4B, and XL-5 LCD Keypad Programming Manual
Version 4
8–8
EVENT
FIRST DIGIT OF
EVENT CODE
✴
SECOND DIGIT OF EVENT CODE
Abort
Quest. #086, Abort
Code; program as 0-F
Quest. #027, User CS Code; program as 000-
015: reports as 0-F
Cancel
Quest. #090, Cancel
Code; program as 0-F
Quest. #027, User CS Code; program as 000-
015: reports as 0-F
Bypass
Quest. #084, Bypass
Code; program as 0-F
Quest. #145, Zone CS Code; program as 000-
015: reports as 0-F
Clock Set
Quest. #089, Clock Set
Code; program as 0-F
Dedicated Code; by installer mode reports
as 1; by #3 reports as F
System Test
Quest. #092, System
Test Funct. Code;
program as 0-F
Quest. #093, System Test CS Code; program
as 000-015: reports as 0-F
AC Loss
Quest. #131, AC Loss
Trouble Type CS Code;
program as 0-F
Quest. #094, AC Loss CS Code; program as
000-015: reports as 0-F
Low Battery
Quest. #131, Low
Battery Trouble Type
CS Code; program as 0-
F
Quest. #095, Low Battery CS Code; program
as 000-015: reports as 0-F
System Error
Quest. #131, System
Error Trouble Type CS
Code; program as 0-F
Quest. #096, System Error CS Code; program
as 000-015: reports as 0-F
Download
Quest. #097, Download
Funct. Code; program as
0-F
Quest. #098, Download CS Code; program as
000-015: reports as 0-F
Zone Alarms
Quest. #110, Alarm
Type CS Code; program
as 0-F (Find Alarm Type
for zone in quest. #158)
Quest. #145, Zone CS Code; program as 000-
015: reports as 0-F
Zone Troubles
Quest. #131, Trouble
Type CS Code; program
as 0-F (Find Trouble
Type for zone in quest.
#159)
Quest. #145, Zone CS Code; program as 000-
015: reports as 0-F
Zone Restores
Quest. #111, Alarm
Type CS Restore Code or
quest. #132, Trouble
Type CS Restore Code;
program as 0-F
Quest. #145, Zone CS Code; program as 000-
015: reports as 0-F
Keypad
Conditions
Quest. #110, Alarm
Type CS Code; program
as 0-F (Find Alarm Type
for condition in quest.
#177)
Quest. #174, Keypad Condition CS Code;
program as 000-015: reports as 0-F
✴
Note: Due to the limitation of representing hexadecimal numbers using a single digit, a
maximum of 16 zones and 16 users can be reported.
Summary of Contents for XL-4
Page 1: ...N9145V2 10 98 6HFXULW 6 VWHP 3URJUDPPLQJ XLGH 9HUVLRQ...
Page 6: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 1 2...
Page 12: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 2 6...
Page 14: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 3 2...
Page 18: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 5 2...
Page 88: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 8 66...