Section 8 - LCD Keypad Programming Questions
8–43
External Relay Address 4
126 XTRIG 4 ATxx
xx (00-40)
Selects a relay in the XL-4705 relay module for this alarm type. The number entered
represents the address as set on the dip switch in the XL-4705 relay module. (00 =Disable,
over 40 is invalid.)
External Momentary Relays
127 MOM TRG ATxx
NNNN
Indicates which of the external relays (1-4) will be activated on a momentary basis with this
Alarm Type. The triggers are selected by placing a Y in the appropriate trigger position. The
FORWARD (INSTANT) and BACKWARD (CODE) keys will move the cursor position to the
desired trigger position, which indicates the trigger number. The TOGGLE (0) key will
change the Yes/No status of the trigger.
If the relays are all N in questions 127 and 128, the relays are considered latched.
External 24-hr Latch Relays
128 24HR TRGATxx
NNNN
Indicates which of the external relays (1-4) will be activated for a maintained duration of the
faulted zone. The triggers are selected by placing a Y in the appropriate trigger position. The
FORWARD (INSTANT) and BACKWARD (CODE) keys will move the cursor position to the
desired trigger position, which indicates the trigger number. The TOGGLE (0) key will
change the Yes/No status of the trigger.
After completion of this question the system will return to question 108 with the next
sequential alarm type. After completion of the last alarm type (alarm type 16) the display
will advance to question 129.
24-Hour relays override momentary and latched relays.
Trouble Types
The system differentiates between fault (or NOT READY) conditions and troubles. Troubles
are latched conditions and require entry of a valid user code or the reset function to clear. In
addition troubles can be defined to transmit signals to the Central Station, and activate
relays or triggers much like an alarm conditions.
System faults will clear as the condition clears. For example, if the system is disarmed and a
non 24 hour zone is activated (door or window opened) the keypad will display the NOT
READY condition. For an LED display this means the zone indicator light solidly on, and on
an LCD display English text showing which zone is not ready. In either case, the indication
will disappear when the door or window is closed. After all faults are removed the system is
READY.
Summary of Contents for XL-4
Page 1: ...N9145V2 10 98 6HFXULW 6 VWHP 3URJUDPPLQJ XLGH 9HUVLRQ...
Page 6: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 1 2...
Page 12: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 2 6...
Page 14: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 3 2...
Page 18: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 5 2...
Page 88: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 8 66...