For example, if the location has a window that they normally leave open, this option will
allow system arming even if the window is open. If the zone is faulted at the time of arming
it will be bypassed.
UL
This shall be programmed as "NO" in UL Listed systems.
Press the 0 key to toggle between the available choices.
Group Enable
152 GRP ENAB
NO
This question indicates whether this zone is part of a group. Grouping allows multiple zones
within the same partition to be grouped together for bypassing and alarm transmission
purposes. The group number will be determined by the alarm type, or trouble type if there is
no alarm condition. For example, the zones defined as part of a group utilizing alarm type 3
will be known as group 3. The zones within group 3 will include all zones within the same
partition that have the same alarm type (or trouble type) and have the group enable question
answered as yes. There can be up to 24 groups per partition (groups 1-16 for alarm types plus
groups 17-24 for trouble types).
Group bypasses can be performed through the command: BYPASS [USER]
✴
1 [GRP #]
where [GRP #] is the group number 01 - 24.
Group unbypasses can be performed through the command: BYPASS [USER]
✴
2 [GRP #]
where [GRP #] is the group number 01 - 24.
Alarms will only be transmitted for the first zone within the group that goes into alarm.
Subsequent alarm conditions from other zones within the group will not transmit to the CS.
Local conditions such as keypad display, keypad sounder and bell output will occur as per
programming and all individual activity will enter the system log.
Restores for groups will only be transmitted after all of the zones within the group have
restored. In addition, the restore code will be transmitted for the first zone number in the
group that went into alarm.
Zone Trouble Enable
153 CS TRB Zxxx
YES
Indicates whether this zone reports trouble conditions to the CS. Press the 0 key to toggle
through the available choices.
UL
For UL Listed systems this shall be "YES".
Zone CS Restore Enable
154 CS REST Zxxx
YES
Indicates whether this zone should transmit restore signals to the Central Station. If
restores are transmitted then they will be handled as follows based on the type of CS format
(questions 004 & 009). Press the 0 key to toggle through the available choices.
Summary of Contents for XL-4
Page 1: ...N9145V2 10 98 6HFXULW 6 VWHP 3URJUDPPLQJ XLGH 9HUVLRQ...
Page 6: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 1 2...
Page 12: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 2 6...
Page 14: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 3 2...
Page 18: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 5 2...
Page 88: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 8 66...