10–1
S E C T I O N 1 0
Keypad Programming Summary
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
The questions listed below will be asked when entering the keypad programming mode on the control
panels.
CS COMMUNICATIONS
001 Callback Number
002 Dump Telephone Number
003 CS #1 Rcvr. Tel. Number
004 CS #1 Receiver Type
005 CS #1 ACCT # (3/4 Digit)
006 CS #1 Parity Selection
007 CS #1 Sescoa Format
008 CS #2 Rcvr. Tel. Number
009 CS #2 Receiver Type
010 CS #2 ACCT # (3/4 Digit)
011 CS #2 Parity Selection
012 CS #2 Sescoa Format
013 Installer Code
014 Dialing Type
015 Dial Tone Detection
016 CS Dialer Enable
017 Rem Commands Enable
018 Remote Disarm Enable
019 Remote Arming
020 Remote Bypass
021 # of Attempts
022 # of Rings to Pickup
023 Extended Antijam
024 Extended Acknowledge
USER ATTRIBUTES
✴✴
025 Select User Number
026 User Authorization Level
027 User CS ID
028 User Partition
Assignment
029 O/C Part Enab.
030 User Master Partition
NOTE: The group of questions
with a double asterisk (
✴✴
)
are selection questions. The
first question of each group
must have the proper choice
selected in order to advance
through the remaining
questions. Otherwise the
group will be skipped.
SYSTEM ATTRIBUTES
031 Zone Expansion Modules
032 External Relay Modules
033 Open/Close CS Rep. Path
034 Part. Auto Arming By Day
035 Clock Set CS Path
036 Test CS Reporting Path
037 Test Frequency
038 Test Time - Hour of Day
039 Test Time - Minute of Day
040 Download Confirm Path
041 Bypass Transmission Path
042 Disable Bypass on Stay
043 Transmit Bypass on
Arming
044 Auto Unbypass Enable
045 Arm Outputs Level
046 Bell Test At Arming
047 Bell Ringback at Closing
048 Sounder Ringback Enable
049 Fire Reset Verification
050 Enable Reset Key
Function
051 En. Rest to Follow Loop
052 Action on Abort
053 En. Multi Part. Mode
054 Enable Quick Arming
055 En Quick Forced Arming
056 Secure Forced Arm Enab
057 Enable Zone Directory
058 Enable Quick Bypass
059 Enable Chime Control
060 Enable Super User (Lev1)
061 En. Multi Part
Arm/Disarm
062 Enab. 7 Digit User Code
063 CSID Inst. Default
064 Keypad Programming
065 Daylight Savings Time
066 AC Line Frequency
SYSTEM TIMING
067 Bell Delay
068 Dialer Delay
069 Exit Delay #1
070 Exit Delay #2
071 Entry Delay #1
072 Entry Delay #2
073 AC Loss Delay
074 Exit Triggers
075 Entry Triggers
076 Timeout #1
077 Timeout #2
078 Timeout #3
079 Global Bell Lockout
080 Local Bell Lockout
081 Global Dialer Lockout
082 Local Dialer Lockout
SYS FUNCT. CODES
083 Enable Zone Tamper
084 Bypass Code
085 Bypass Restore
086 Abort Code
087 Opening Code
088 Closing Code
089 Clock Set Code
090 Cancel Code
091 Cancel Path
092 System Test Funct. Code
093 System Test CS Code
094 AC Loss CS Code
095 Low Battery CS Code
096 System Error CS. Code
097 Download Funct. Code
098 Download CS. Code
099 Buzzer on AC Loss
100 Buzzer on Low Battery
101 Buzzer on System Error
102 24 Hour AC Trouble
103 24 Hour Low Battery
104 24 Hour System Error
105 Trouble Type AC Failure
106 Trouble Type Low Battery
107 Trouble Type System
Error
Summary of Contents for XL-4
Page 1: ...N9145V2 10 98 6HFXULW 6 VWHP 3URJUDPPLQJ XLGH 9HUVLRQ...
Page 6: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 1 2...
Page 12: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 2 6...
Page 14: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 3 2...
Page 18: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 5 2...
Page 88: ...XL 4 XL 4B and XL 5 LCD Keypad Programming Manual Version 4 8 66...