Lumina 35
Installer
47
Address
Setting of the address of the digital input.
Registration input
Setting the type of measurement:
•
MANUALLY
: Enables you to enter the amount of today manually.
•
SLOW PULSE
: Measuring instruments with a maximum frequency of 20 pulses per
second (20 Hz).
•
QUICK PULSE
: Measuring instruments with a maximum frequency of 20 pulses per
second (20 Hz) (only use when there is a link with a switch clock).
•
CONTACT
: As long as the sensor makes contact, the value will be added up
cumulatively. The amount is therefore determined by time the contact is
HIGH
.
Unit per pulse
Setting of the unit that corresponds to one pulse. (only with measurement type:
SLOW
PULSE
or
QUICK PULSE
)
Unit per minute*
Setting of the number of 'units' measured per minute. This option is only available if
Display=AMOUNT
. (only with measurement type:
CONTACT
)
Display
*
Setting how the unit is displayed:
•
AMOUNT
: number 'units' per minute (
Amount per min.
).
•
TIME
: the time the contact makes contact. (only with measurement type:
CONTACT
).
Unit today*
Readout of the unit measured today. Reset this value to start all registration from zero
again.
Input status
*
Readout of the actual input status.
HIGH
or
LOW
. (only with measurement type:
CONTACT
).
Total
Readout of the total unit measurements.
The control computer can carry out various outside measurements. These measurements can also be done by
another control computer in the network.
INSTALLER
→
OUTSIDE CLIMATE
→
tab page
Temp/RH
Measurement outside
temp.
Setting if the control computer carries out outside measurement concerned itself (
INT
)
or via the communication network (
COMM
). Only enter the address of the input if INT is
selected.
Address
Setting the address of the analog input.