Lumina 35
Explanation control functions
9
The settings that have to be made for the tunnel part (T-part) correspond broadly with the settings for the M/MT-
part. Instead of the ventilation position in % you enter the offset temperature for the positions. At the first position
this offset temperature is linked to start temperature venti calculated bandwidth. Each following position is
linked to the previous position via an offset. In other words: the control computer never controls in between two
positions.
M/MT-
phase
Exhaust
Inlets
Ctrl.
Control-
lable/Extra
Relays
Inlet
(%)
Tun
(%)
Press
. (Pa)
Cap.
(m3/h)
ºC
1
2
3
1
2
3
4
5
6
7
8
9
10
T1
2.0
0
0
0
1
1
1
1
1
1
0
0
0
0
50
25
0
120000
T2
1.0
0
0
0
1
1
1
1
1
1
1
0
0
0
0
50
0
140000
T3
1.0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
75
0
160000
T4
1.0
0
0
0
1
1
1
1
1
1
1
1
1
0
0
100
0
180000
T5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
T6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
T7
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
T8
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
T9
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
T10
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Modulating control can be used to control the ventilation level in percentages of a cycle time. The control
computer activates/deactivates the fans according to a fixed pattern. This supplies fresh air in short repeated
periods. Modulating fans are shown in the combi-table by the letter M.
Example: Modulating ventilation
The required ventilation position of the fans: 21%
The control computer will control the fans on for 50% of the set cycle time. The ventilation is off for 50%
of the time.
Determining the ventilation position
The control computer determines the use of air inlets, extra inlets and fans based on the combi-table. The
example below shows a combi-table with modulating fans. The relay fans will do 20.000 m3 each.