Lumina 35
House setup
28
This chapter explains all the options in the
HOUSE SETUP
menu.
In
HOUSE SETUP
select the parts of the control computer you intend to use. The control computer will only
display data relevant to you in the screens. Parts not used, will not be shown. Most codes are self explanatory.
HOUSE SETUP
→
tab page
Setup
Heating
Setting of the number of heating units to be used.
Cooling
Setting of the number of cooling units to be used.
Pressure measurement
Setting indicating if pressure measurement is used. If pressure measurement is used,
the pressure can influence exhaust ventilation or air inlets (
YES
/
NO
).
RH measurement
Setting indicating if RH measurement is used. If RH measurement is used, the RH
influence on heating, cooling and ventilation can be used.
Humidification
Setting indicating if humidity control is used. This can only be used in combination with
RH-measurement.
Measurement outside
temp.
Setting indicating if outside temperature measurement is used. If outside temperature
measurement is used the outside temperature can influence a number of controls.
Measurement outside
RH
Setting indicating if outside RH measurement is used. Using absolute moisture
calculation, the control computer determines if the outside air is suitable for
dehumidification.
Measurement wind
Setting indicating if wind direction and wind speed measurement is used. If wind
direction and wind speed measurement is used the wind can influence a number of
controls.
Multiple inlets
Partial inlet control, whereby only some of the inlets are controlled. The control will be
corrected.
Number of minivents
Setting of the number of minivents used in the house. This is mainly important with air
inlets.
Half House Brooding
Partial use of available house space.
Number of minivents
Setting of the number of minivents used during Half-House Brooding.