Lumina 35
Installer
41
INSTALLER
→
HEAT COOL HUM
→
tab page
Heat
Description
Setting of the name of the function.
Temp. Inputs
Setting the addresses of the analog inputs. If the temperature sensors have not been
assigned, the control computer will use the house temperature.
Control
Setting of the heating control type:
LINEAR
or
RELAY
.
Output address
Setting of the analog output address (choice
LINEAR
control) or relay output address
(choice
RELAY
control).
Relay type
Setting of the type of relay control (
ON/OFF
/
Modulating
).
Analog type*
Setting indicating the analog control type
Precontrol
Setting indicating if the heat demand should be transmitted to a central boiler control
(precontrol).
INSTALLER
,
HEAT COOL HUM
, tab page
OptiSec
Band
Setting of the maximum correction (
Band
). The control computer can increase the
setpoint heating until this equals the setpoint house temperature.