Lumina 35
Explanation control functions
7
Extra fans can only be switched on or off via a relay. They are usually used when the controllable fans are
running at maximum or in combination with controllable fans to achieve a gradual increase in ventilation.
Figure 5: Example of an extra fan switched on and off from the control computer by a relay
The control computer determines the use of air inlets, extra inlets and fans based on the combi-table. Below is an
example of a combi-table. This may differ to your own combi-table, for example, because you use a different
number of extra fans. The combi-table shows the required values at successive positions (M1 thru M10 in the
example). The relay fans will do 20.000 m3 each and the controllable part is 25.000 m3.
M/MT-
phase
Exhaust
Inlets
Ctrl.
Mod.
Control-
lable/Extra
Relays
Inlet
(%)
Tun
(%)
Press
. (Pa)
Cap.
(m3/h)
(%)
1
2
3
1
2
3
4
5
6
7
8
9
10
M1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
22
250
M2
20
100
0
0
0
0
0
0
0
0
0
0
0
0
0
20
0
20
25000
M3
21
25
0
0
0
1
0
0
0
0
0
0
0
0
0
21
0
20
26250
M4
36
100
0
0
0
1
0
0
0
0
0
0
0
0
0
36
0
20
45000
M5
37
25
0
0
0
1
1
0
0
0
0
0
0
0
0
37
0
18
46250
M6
52
100
0
0
0
1
1
0
0
0
0
0
0
0
0
52
0
18
65000
M7
68
100
0
0
0
1
1
1
0
0
0
0
0
0
0
60
10
16
85000
M8
84
100
0
0
0
1
1
1
1
0
0
0
0
0
0
80
10
14
105000
M9
100
100
0
0
0
1
1
1
1
1
0
0
0
0
0
100
15
14
125000
M10
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
The combi-table also contains the ventilation capacity. This is used to determine the ventilation position if control
is based on ventilation capacity per hour per animal (m3/h/animal).
The required pressure in the combi-table is used to control the inlet based on the under pressure in the house.
See Optimisation based on pressure page 10.