Lumina 35
House setup
30
The
warm climate table
can be used to enable the tunnel inlets in minimum ventilation. By using this
setting coolpads can be used earlier in the combi table to cool the air. This is energy efficient and will
provide a more stable temperature for the animals. The
warm climate table
will be only applicable when
the outside temperature is heigher than
Setpoint house
+
Temperature offset
for a minimum time of the
set
Switch delay
.
Make sure coolpads can be modulated sufficiently to a low capacity.
HOUSE SETUP
→
tab page
Clocks
Registration
Setting indicating if registration inputs are used.
Use clocks
Setting indicating if clocks are used.
Light clock
Setting indicating if light clocks are used.
Light relay
Setting indicating if light relays are used.
Light control
Setting indicating if light control is used.
Light measurement
Setting indicating if light measurement in the house is used.
Feed clock
Setting indicating if feed clocks are used.
Feed registration
Setting indicating if feed registration is used.
Water clock
Setting indicating if the amount of water must be registered. A connected water meter is
required. Enter the water meter data at registration.
Water registration
Setting indicating if water registration is used.
Extra clock
Setting indicating if extra clocks are used.