XTP II CrossPoint Series • Maintenance and Modifications
85
Replacing and Terminating the Power Cable (XTP II CrossPoint 6400)
The XTP II CrossPoint 6400 has an attached power cable with a standard North American
220 V plug. For matrix switchers outside of North America, the attached power cable is
unterminated. The plug can be replaced with a termination that is more appropriate to
where you install the matrix switcher and the entire cable can be replaced.
WARNING:
High leakage current, earth connection is essential before connecting
the supply.
AVERTISSEMENT :
Courant de fuite éléve, le raccordement à la terre est indispensable
avant le raccordement au réseau.
ATTENTION:
•
The outlet or junction box must be installed near the equipment and be easily
accessible.
•
La prise de courant ou la boîte de jonction doivent être installées près du dispositif
et être facilement accessibles
•
The installation location must provide short circuit and overcurrent protection, to a
minimum of 20 A.
•
Le lieu d’installation doit disposer d’une protection contre les courts-circuits et la
surtension de 20 A minimum.
•
Do
NOT
use an extension cord.
•
Ne
PAS
utiliser de rallonge électrique.
Replacing or Installing the Power Plug
Replace or install the 220 VAC power plug as follows:
ATTENTION:
•
Extron recommends that this procedure be performed by a licensed electrician
only
.
•
Extron recommande que cette tâche soit exécutée par un électricien agréé
uniquement
.
•
The installation location must provide short circuit and overcurrent protection, to a
minimum of 20 A.
•
Le lieu d’installation doit disposer d’une protection contre les courts-circuits et la
surtension de 20 A minimum.
•
Do
NOT
use an extension cord.
•
Ne
PAS
utiliser de rallonge électrique.
1.
If the matrix switcher is powered, unplug it or remove power from the power outlet or
junction box that powers the matrix switcher.
2.
Locally acquire a 220 VAC power connector that is standard for the region where the
switch is to be installed.
3.
If necessary, cut the power cable just before the existing 220 V plug.
4.
Trim the jacket back and strip the insulation from the line, neutral, and ground wires.
5.
Connect the wires to the appropriate prongs of the power plug and assemble the plug,
as detailed in the instructions that accompanied the plug.
6.
Plug the power cord into the 220 VAC power outlet.