XTP II CrossPoint Series • Front Panel Operation
27
A
— Press an input button to select an input, preset, or audio level. Input
buttons 1 and 2 also select background illumination settings (see
B
— Press an output button to select an output or preset.
C
Enter
,
Preset
,
View
(
<
), and
Esc
(
>
) buttons. Press
them for the following:
•
Enter button
— Press this button to accept pending changes to settings or
presets. In conjunction with the other control buttons, this button also enables
Serial Port Configuration mode.
•
Preset button
— Press this button to enable Preset mode. In conjunction with the
other control buttons, this button also enables Serial Port Configuration mode.
•
View (
<
) button
— Press this button to enable View mode or decrease the input
audio level or output volume. In conjunction with the other control buttons, this
button also enables Serial Port Configuration mode or a Front Panel Lockout mode.
•
Esc (
>
) button
— Press this button to cancel pending changes to settings or
presets or increase the input audio level or output volume. In conjunction with the
other control buttons, this button also enables Serial Port Configuration mode or a
Front Panel Lockout mode.
D
— Include the
Audio
and
Video
buttons. Press them for the following:
•
Video button
— Press this button to select video for ties or RS-232 protocol in
Serial Port Configuration mode. With the
Audio
button, this button also performs a
system reset.
•
Audio button
— Press this button to select audio for ties or RS-422 protocol in
Serial Port Configuration mode. With the
Video
button, this button also performs a
system reset.
E
— Connect a host device (such as a PC) to the USB mini-B
connector.
F
— Light when power is applied to associated power supply.
NOTES:
•
The XTP II CrossPoint 1600 has two power supplies with two optional,
redundant power supplies.
•
Left Primary LED
— Corresponds to the 12 V power supply.
•
Right Primary LED
— Corresponds to the 48 V power supply (also
provides XTP remote power.
•
Left Redundant LED
— Corresponds to the redundant 12 V power supply.
•
Right Redundant LED
— Corresponds to the redundant 48 V power
supply.
•
The other XTP II CrossPoint Series matrix switchers have four power supplies.
•
LEDs 1 and 2
— Correspond to the two primary 12 V power supplies.
•
LED 3
— Corresponds to the redundant 12 V power supply.
•
LED 4
— Corresponds to the 48 V power supply (also provides XTP remote
power).
•
Green
— Indicates the power supply is operating within normal tolerances.
•
Red
— Indicates the power supply is operating outside normal tolerances or has
failed.
G