XTP II CrossPoint Series • SIS Configuration and Control
57
XTP Setup Parameters
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Enable/Disable XTP Remote Power
Enable or disable input power and
report status
E
I
X30!
*
X39!
POEC
}
PoecI
X30!
*
X39!
*
X39@
*
X39$]
Unsolicited response when an “amount power request”
changes:
PoecI
X30!
*
X39!
*
X39@
*
X39$]
Enable or disable input power and
report status, all inputs
E
I
X39!
*POEC
}
PoecI00*
X39!
1
*
X39!
2
*
X39!
3
*
...
X39!
n
]
Enable or disable output power and
report status
E
O
X30#
*
X39!
POEC
}
PoecO
X30#
*
X39!
*
X39@
*
X39$]
Unsolicited response when an “amount power request”
changes:
PoecO
X30#
*
X39!
*
X39@
*
X39$]
Enable or disable output power and
report status, all outputs
E
O
X39!
*POEC
}
PoecO00*
X39!
1
X39!
2
X39!
3
...
X39!
n
]
View XTP Power Settings
View XTP input power
(enable/disable and status)
E
I
X30!
POEC
}
X39!
*
X39@
*
X39$]
View power setting per input
View all XTP input power
(enable/disable)
E
IPOEC
}
X39!
1
X39!
2
X39!
3
...
X39!
n
]
Verbose modes 2/3:
PoecI00*
X39!
1
*
X39!
2
*
X39!
3
*
...
X39!
n
]
View XTP output power
(enable/disable and status)
E
O
X30#
POEC
}
X39!
*
X39@
*
X39$]
View power setting per output.
Verbose modes 2/3:
PoecO
X30#
00*
X39!
1
*
X39!
2
*
X39!
3
*...
X39!
n
]
View ALL XTP output power
(enable/disable)
E
OPOEC
}
X39!
1
X39!
2
X39!
3
...
X39!
n
]
Verbose modes 2/3:
PoecO00*
X39!
1
*
X39!
2
*
X39!
3
*...
X39!
n
]
Power Usage
Query XTP power usage
E
TPOEC
}
X39$
*
X39%]
Power usage for all enabled
power devices.
Verbose modes 2/3:
PoecT
X39$
*
X39%]
KEY:
X30!
= Input number
01
to maximum number of inputs for your switcher model
X30#
= Output number
X39!
= 0 = Disable (default), 1 = Enable
X39@
= Amount of power requested
X39$
= Power status
0
= Unpowerable endpoint
1
= Power is being provided to the endpoint
2
= Power available for the endpoint, but disabled
3
= No power available for the endpoint, but enabled
4
= Fault
X39%
= Error status
0
= Power status OK
1
= Power supply fault