Installing and Removing the Internal 600 Watt AC Power Supply (15412)
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
121
Removing an EPS-LD unit
To remove an EPS-LD unit:
1
Disconnect the AC power by removing the plug from the wall.
2
Disconnect the AC power cord from the EPS-LD unit.
3
Disconnect the cable between the Extreme switch and the EPS-LD unit.
4
Remove the screws from the EPS-LD mounting brackets.
5
Slide the EPS-LD unit out of the rack.
Installing and Removing the Internal 600 Watt AC Power
Supply (15412)
The Summit 300-48 600 Watt AC power supply (15412) is designed to be used in the Summit 300-48
switch. While powering the Summit 300-48, the 600 W power supply is capable of providing 450 W of
power to Power over Ethernet (PoE) devices connected to the 48 primary PoE ports. Refer to the
Summit 300-48 Release Notes to determine the total available power at each port. You can obtain copies
of these documents at the Extreme Networks web site at:
http://www.extremenetworks.com/services/
The switch has two power supply bays, so a redundant power supply can be installed. When used in
redundant mode, the power supplies are hot-swappable. You can add a second power supply without
powering off the switch. If redundant power supplies are installed, you can remove one of them
without powering off the switch.
This section includes the following procedures:
•
Installing an Internal 600-Watt Power Supply on page 122
•
Removing an Internal Power Supply on page 123
•
Installing a cable retaining bracket
•
Removing cable retaining bracket
The Summit 300-48 comes with a minimum of one power supply pre-installed at the factory. Switches
with one power supply have a metal cover plate in place of the second supply. If you install a second
power supply, be sure to retain the cover plate in case you later decide to use only one supply.
Table 23:
LED status for EPS-LD Power LED
Power LED
Indicates
Green, solid
Off
The external power supply is operating normally.
The external power supply is not connected.
Summary of Contents for Alpine 3802
Page 18: ...18 Extreme Networks Consolidated i and e Series Hardware Installation Guide Preface ...
Page 19: ...Part 1 Common Features ...
Page 20: ......
Page 25: ...Part 2 Site Planning ...
Page 26: ......
Page 56: ...56 Extreme Networks Consolidated i and e Series Hardware Installation Guide Site Preparation ...
Page 57: ...Part 3 Summit Switch ...
Page 58: ......
Page 137: ...Part 4 Alpine Switch ...
Page 138: ......
Page 213: ...Part 5 BlackDiamond Switch ...
Page 214: ......
Page 303: ...Part 6 Switch Operation ...
Page 304: ......
Page 307: ...Part 7 Appendixes ...
Page 308: ......