96
ENGINE MANAGEMENT MODULE (EMM)
EMM DIAGNOSTICS
times the event occurred, operating hours of first
and last occurrence.
Hard Faults
A hard fault is a code that currently exists. Hard
faults become stored faults only if the outboard is
running.
Persistent Faults
The
Persistent Faults
screen provides a history of
all previously stored codes, including code num-
ber, the number of times the event occurred, and
operating hours of the last occurrence.
Persistent faults cannot be erased.
Static Tests
Static Tests perform diagnostic testing of specified
components.
Ignition Test
Use the diagnostic software to test each ignition
circuit. Refer to
Static Spark Test
on p. 116.
Check each circuit for continuity between the
EMM
and individual coil. Check the resistance of
the ignition coil windings. Refer to
Ignition Coil
Tests
on p. 128.
Fuel Test
Use the diagnostic software to test each fuel injec-
tor. The injector should make an audible click.
Make sure the injector being monitored is wired
correctly. If the injector activates, the
EMM
and
injector circuits are not at fault. If the fuel injec-
tor(s) will not fire during the diagnostic tests,
check the continuity of the injector circuit. Refer to
Fuel Injector
Resistance Test
on p. 164.
Stored Faults Review Screen
005143
Hard Faults Review Screen
005145
Static Tests Screen
005166
Summary of Contents for E-tec 75 HP
Page 1: ......
Page 233: ...233 POWERHEAD POWERHEAD VIEWS 10 POWERHEAD VIEWS Port Short Block Starboard Short Block ...
Page 234: ...234 POWERHEAD POWERHEAD VIEWS Port Dressed Powerhead Starboard Dressed Powerhead ...
Page 235: ...235 POWERHEAD POWERHEAD VIEWS 10 Front ...
Page 236: ...236 POWERHEAD POWERHEAD VIEWS Rear ...
Page 237: ...237 POWERHEAD POWERHEAD VIEWS 10 Top ...
Page 298: ...S 2 ...
Page 344: ......