ELECTRICAL AND IGNITION
FLYWHEEL SERVICING
FLYWHEEL SERVICING
IMPORTANT:
Weak flywheel magnets can
cause low alternator output and affect outboard
performance. Weak flywheel magnets can also
cause low readings on ignition test equipment
such as the peak-reading voltmeter, which might
cause unnecessary replacement of ignition com-
ponents.
An accurate test of alternator output can help
determine the flywheel’s condition. Refer to
CHARGING SYSTEM TESTS
on p. 130.
Removal
Remove the electrical cover from flywheel cover.
Disconnect wiring for MWS harness and remove
wiring from cover.
Remove fuse holder from flywheel cover.
Lift flywheel cover to remove.
WARNING
To prevent accidental starting while ser-
vicing, disconnect the battery cables at
battery.
1.
Electrical cover
002084
1.
Electrical cover removed
002085
1
1
1.
MWS harness
002086
1.
Fuse holder
002094
002087
1