287
TRIM AND TILT
ROUTINE INSPECTIONS
13
ROUTINE INSPECTIONS
General
Check for external signs of fluid leakage. Correct
causes as necessary.
Check the battery and make sure it is in good
operating condition.
Reservoir Fluid
Check reservoir fluid level every three years or
every 300 operating hours. System capacity is
approximately 20 fl. oz. (620 ml).
•
Tilt the outboard and engage the tilt support.
•
Remove the fill plug.
•
Add
Evinrude/Johnson
Biodegradable TNT
Fluid, as needed, to bring level to the bottom of
the fill plug threads.
•
Install the fill plug and torque 45 to 55 in. lbs. (5
to 6 N·m).
•
Disengage tilt support.
•
Cycle the unit at least five complete cycles to
purge all air from the system. When cycling the
unit, hold the trim switch ON an additional 5 to
10 seconds after the unit reaches the end of its
travel before activating the switch in the oppo-
site direction.
Manual Release Valve
Check the manual release valve with a torque
wrench.
IMPORTANT:
The valve must be torqued 45 to
55 in. lbs. (5 to 6 N·m).
Stern Brackets
Inspect the stern brackets for binding with the
swivel bracket in the thrust rod area. Retorque the
tilt tube nuts as follows:
•
Tighten the tilt tube nuts to a torque of 40 to 45
ft. lbs. (54 to 60 N·m).
•
Loosen one nut 1/8 to 1/4 turn after torquing.
1.
Reservoir cap
004278
1
Summary of Contents for E-tec 75 HP
Page 1: ......
Page 233: ...233 POWERHEAD POWERHEAD VIEWS 10 POWERHEAD VIEWS Port Short Block Starboard Short Block ...
Page 234: ...234 POWERHEAD POWERHEAD VIEWS Port Dressed Powerhead Starboard Dressed Powerhead ...
Page 235: ...235 POWERHEAD POWERHEAD VIEWS 10 Front ...
Page 236: ...236 POWERHEAD POWERHEAD VIEWS Rear ...
Page 237: ...237 POWERHEAD POWERHEAD VIEWS 10 Top ...
Page 298: ...S 2 ...
Page 344: ......