148
ELECTRICAL AND IGNITION
ELECTRIC STARTER SERVICING
Apply
Locquic Primer
and
Screw Lock
to the
threaded portion, and install the two thru-bolts.
Torque bolts 100 to110 in. lbs. (11 to 12.5 N·m).
Lubricate the splines (helix) of starter pinion shaft
with
Starter Bendix Lube
. DO NOT use liquid or
aerosol spray lubricants.
Install pinion, spacer and spring.
Install spacer and retaining clip. Spacer must be
raised to cover clip completely.
To test the assembly and operation of the starter,
refer to
No Load Current Draw Test
on p. 137.
Installation
Apply
Triple-Guard
grease to the threads of the
two starter screws, the double-ended stud, and
also to the washers.
Position the starter and install the screws and
washers. Torque to 168 to 192 in. lbs. (19 to 21
N·m).
Attach starter positive (+) cable to post with lock
washer and nut; tighten securely. Coat connec-
tions with
Black Neoprene Dip
.
Attach the battery negative (–) cable to the starter
frame. Attach the starter positive (+) cable to the
starter’s positive terminal.
Coat all electrical connections with
Black Neo-
prene Dip
.
002306
002307
002305
002311
002297
1.
Black Neoprene Dip
002292
1
1
Summary of Contents for E-tec 75 HP
Page 1: ......
Page 233: ...233 POWERHEAD POWERHEAD VIEWS 10 POWERHEAD VIEWS Port Short Block Starboard Short Block ...
Page 234: ...234 POWERHEAD POWERHEAD VIEWS Port Dressed Powerhead Starboard Dressed Powerhead ...
Page 235: ...235 POWERHEAD POWERHEAD VIEWS 10 Front ...
Page 236: ...236 POWERHEAD POWERHEAD VIEWS Rear ...
Page 237: ...237 POWERHEAD POWERHEAD VIEWS 10 Top ...
Page 298: ...S 2 ...
Page 344: ......