All rights reserved. Reproduction as well as electronic duplication of this guide, complete or in part, requires the written consent of ESERA-
Automation or E-Service GmbH. Errors and technical modification subject to change.
©
ESERA-Automation, E-Service GmbH 2019
www.esera.de
Programming Manual Controller-Gateway-Station V1.0 R1.1
Page 37 of 77
9.7.
OWD FORMAT 0, 1 or 2
Defines the number of decimal places for measured values of the temperature sensors.
Selectable range: 0 - 2 decimal places
Factory setting: 2 decimal places, e.g. 23.45 °C are used as output value 2345
Command
: SET,OWD,FORMAT,0 - 2
9.8.
DS2408 INV ON/OFF
Inverting of the outputs of DS2408 devices (8-fold I/O). This inversion is necessary due to the electrical function of
the "Open Drain" outputs of the DS2408 chips.
Selectable states: ON = 1 / OFF = 0
Factory setting: ON = 1
Command
: SET,OWD,DS2408INV,0 or 1
9.9.
OWD ID ON/OFF
Switching of the output of the module name either with "OWD" or the own serial number.
Selectable states: ON = 1 / OFF = 0,
0 = output "OWD", 1 = output of the block serial number
Factory setting: OFF = 0
Command
: GET,SYS,OWDID,0 or 1
9.10.
DEBUG 0, 1 or 2
Different outputs are output for the current activity of the 1-Wire Controller / 1-Wire Gateway. For example, the
data raw values of 1-Wire devices are output.
Selectable states: 0 = no debug (additional information), 1 and 2 = debug outputs
Note: The debug output is not specified. It is intended to provide information about the current workload of the 1-
Wire Controller / 1-Wire Gateways and also for data output of the 1-Wire devices.
Factory setting: 0
Command
: SET,SYS,DEBUG,0/1/2
9.11.
OWDIDFormat, output format of 1-Wire serial numbers
There are basically two ways to output the 1-Wire serial number of a 1-Wire device. The output of the serial
number can be displayed on the left or right, starting with the family code. There is no fixed default for this
according to the 1-Wire specification.
The output formatting of the 1-Wire serial number can also be switched, starting with firmware V1.18_41.
The serial numbers of the 1-Wire devices can be looked up at different list outputs (List0, List1, etc.) or at the
output of the OWD numbers.
Example: In the following two output possibilities are represented. The numbers 28 and 26 in our example stand
for the family code of the 1-Wire blocks, by means of which the 1-Wire blocks and their functions can be clearly
identified.