SC-F9200 Series
Revision C
TROUBLE SHOOTING
Remedies for Service Call Error
46
SE Group Confidential (Related Staff Only)
113F
CR Motor
lock error
The CR Motor was driven at a speed abnormally
slower than a predetermined one during operation.
CR Encoder cable is damaged.
CR Motor cable is damaged.
Irregular load
CR Encoder failure
CR Motor failure
1. Is there any problems such as damaged cable in the
connections below?
CR Encoder to SUB Board (CN102)
CR Motor to SUB-M Board (CN1)
2. Does the CR Encoder work properly? Check it
using the Service Program.
2. Replace the CR Motor.
1229
PF Motor
oscillation error
The control terminal (Vre terminal) of the PF Motor
driver has shorted out.
1. Is the PF Motor driver on the Main Board
damaged?
2. Is there any foreign materials around the PF Motor
driver?
1. Remove the foreign material.
2. If the error still occurs, replace the Main Board.
122A
PF Motor
overload error
Overcurrent to the PF Motor was detected.
PF Encoder cable is damaged.
PF Motor cable is damaged.
Irregular load
PF Encoder failure
PF Motor failure
Does the PF Encoder work properly? Check it using
the Service Program.
1. Replace the PF Encoder.
2. Replace the Main Board.
122B
PF Motor
over speed error
Contamination of PF Encoder
Increase of load (paper jam)
Cable disconnection
1. Is the PF Encoder contaminated?
2. Is there any foreign materials on the paper path?
3. Check the Interface cable for breaking.
1. Replace the PF Encoder.
2. Replace the FFC of the PF Encoder.
3. Replace the PF Motor.
122C
PF Motor
reversing error
PF Motor rotated in the reverse direction.
---
Replace the PF Motor.
122D
PF Motor
driving time-out error
Abnormally-long driving duration of the PF Motor
was detected.
Irregular load
Firmware becomes out of control.
---
Table 2-4. Troubleshooting for Service Call Error
Code
Error Name
Cause
Check Item
Remedy
Summary of Contents for SC-F9200 series
Page 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Page 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Page 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...
Page 389: ...SE Group Confidential Related Staff Only C H A P T E R 6 APPENDIX ...