SC-F9200 Series
Revision C
TROUBLE SHOOTING
Remedies for Print Quality Troubles
64
SE Group Confidential (Related Staff Only)
Bandings in the carriage movement
direction.
The Print Head has not been adjusted
properly.
Have the following adjustments been made properly?
CR Direction Head Slant Adjustment
PF Direction Head Slant Adjustment
Carry out the adjustments correctly.
CR Direction Head Slant Adjustment
PF Direction Head Slant Adjustment
Improper PG adjustment
1. Is the paper thickness setting correct?
2. Has the PG adjustment been made properly?
1. Correct the paper thickness setting.
CR Scale or CR Encoder failure
1. Is the CR Scale damaged or contaminated?
2. Is the CR Scale attached properly?
3. Is the CR Encoder installed correctly?
1. Clean the CR Scale.
2. Reinstall the CR Scale and CR Encoder.
3. Replace the CR Scale
and CR
Encoder
.
The tension of the CR Timing Belt is
not proper.
---
Correct the tension of the CR Timing Belt.
Suction setting failure
Suction fan failure
1. Is there any slack in the loaded paper?
2. Does the Suction fan work normally? Check it using the
Service Program.
1. Make the suction setting properly.
2. Replace the Suction fan.
Lubrication on the CR moving parts is
insufficient.
Has the oil pad of the CR Unit dried out?
If the pad is dry, lubricate it.
Table 2-5. Print Quality Troubles
Symptom
Cause
Check Item
Remedy
Summary of Contents for SC-F9200 series
Page 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Page 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Page 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...
Page 389: ...SE Group Confidential Related Staff Only C H A P T E R 6 APPENDIX ...