SC-F9200 Series
Revision C
ADJUSTMENT
Other Printer Checks and Adjustments
353
SE Group Confidential (Related Staff Only)
4.15.3 Heater Function Check
EXECUTION MODE
Normal Mode
PROCEDURE
1.
Turn the printer ON.
2.
Start the Service Program and select
Heater Function Check
.
3.
Click
[Run]
. The selected heater(s) starts to heat up and reaches a predetermined
temperature after about 5 minutes.
4.
Touch the heater(s) and check that it is warm.
If the heater(s) temperature does not reach the predetermined level within 10
minutes, an error is displayed.
5.
Click
[Finish]
.
6.
Turn the printer OFF to finish the adjustment.
Figure 4-74. [Heater Function Check] Screen
C A U T I O N
In a cool environment, it may take a longer time to heat up the
heaters. (If the ambient temperature is 10 degrees C, it may take 20
minutes or longer.)