SC-F9200 Series
Revision C
TROUBLE SHOOTING
Remedies for Service Call Error
54
SE Group Confidential (Related Staff Only)
1A23
RTC data
invalid error
The various absolute time settings stored on the
NVRAM are abnormal.
Reset the date and time settings of the RTC using the
Service Program.
If the error still occurs after resetting the date and
time, perform the followings.
1. Replace the RTC backup battery.
2. Replace the Main Board.
1A26
RTC Access
T/O error
The RTC circuit on the Main Board malfunctions.
---
1. Turn the power off and remove the RTC backup
battery.
2. After several seconds, re-attach the battery and
turn the power back on.
3. Reset the date and time settings of the RTC using
the Service Program.
1A37
Thermistor error
The Head FFC is not connected correctly.
A temperature out of a predetermined range was
detected by the Head thermistor.
Head thermistor failure
Is the Head FFC connected properly without being
connected at an angle and any abnormalities such as
ripped terminal cover?
1. Replace the Head FFC.
2. Replace the Print Head.
1A38
Transistor
environmental
temperature error
Transistor failure
A temperature out of a predetermined range was
detected by the Head thermistor.
---
Replace the Print Head.
1A39
Head error
Connection failure of the Head FFC.
Electric parts or components are damaged due to
improper Head FFC connection such as connecting
it at an angle.
The drive circuit in the Print Head is damaged.
The fuse of the Main Board has blown.
Is the Head FFC connected properly without being
connected at an angle and any abnormalities such as
ripped terminal cover?
1. Replace the Head FFC.
2. Replace the Print Head.
3. Replace the Main Board.
1A3C
CR Motor Cooling Fan
lock error
Cable is damaged
Fan failure
---
1. Reconnect the cable.
2. Replace the CR Motor Cooling Fan.
1A3D
PF Motor Cooling Fan
lock error
Cable is damaged
Fan failure
---
1. Reconnect the cable.
2. Replace the PF Motor Cooling Fan.
1A3D
Power Supply Board
Cooling Fan lock error
Cable is damaged
Fan failure
---
1. Reconnect the cable.
2. Replace the Power Supply Board Cooling Fan.
1A41
Head rank ID
input error
An invalid Head rank ID was written to the NVRAM. Check the Head rank ID using the Service Program.
Rewrite the Head rank ID with a correct one.
Table 2-4. Troubleshooting for Service Call Error
Code
Error Name
Cause
Check Item
Remedy
Summary of Contents for SC-F9200 series
Page 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Page 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Page 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...
Page 389: ...SE Group Confidential Related Staff Only C H A P T E R 6 APPENDIX ...