SC-F9200 Series
Revision C
TROUBLE SHOOTING
Remedies for Service Call Error
48
SE Group Confidential (Related Staff Only)
141A
Pump Motor
overload error
Overcurrent to the Pump Motor was detected.
Pump Motor encoder cable disconnection
Pump Motor cable disconnection
Irregular load
Pump Motor encoder failure
Pump Motor failure
1. Is there any problems such as damaged cable in the
connections below?
Pump Motor (Pump Motor encoder) to Main
Board (CN210/CN230)
2. Does the Pump Motor encoder work properly?
Check it using the Service Program.
Replace the Pump Motor encoder and Pump Motor
(Pump Cap Unit 2).
141B
Pump Motor
over speed error
The Pump Motor was driven at a speed faster than a
predetermined one during deceleration.
Irregular load
Pump Motor encoder failure
Pump Motor driver failure
Does the Pump Motor encoder work properly? Check
it using the Service Program.
1. Replace the Pump Motor encoder (Pump Cap
2. Replace the Main Board.
141C
Pump Motor
reversing error
The number of occurrences of reversing the Pump
Motor has reached a predetermined limit.
The polarity of Pump Motor encoder cable is
opposite.
The polarity of Pump Motor cable is opposite.
1. Is there any problems such as damaged cable in the
connections below?
Pump Motor (Pump Motor encoder) to Main
Board (CN210/CN230)
2. Does the Pump Motor encoder work properly?
Check it using the Service Program.
Replace the Pump Motor encoder (Pump Cap Unit
2).
141D
Pump Motor
driving time-out error
Abnormally-long driving duration of the Pump Motor
was detected.
Irregular load
Firmware becomes out of control.
---
Table 2-4. Troubleshooting for Service Call Error
Code
Error Name
Cause
Check Item
Remedy
Summary of Contents for SC-F9200 series
Page 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Page 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Page 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...
Page 389: ...SE Group Confidential Related Staff Only C H A P T E R 6 APPENDIX ...