SC-F9200 Series
Revision C
ADJUSTMENT
CR Related Adjustments
297
SE Group Confidential (Related Staff Only)
4.10 CR Related Adjustments
4.10.1 CR Belt Tension Check
REQUIRED TOOLS
Sonic tensimeter U-507
Any tools to flip the belt
STANDARD VALUE
48 ± 2 N
EXECUTION MODE
Normal Mode
PROCEDURE
1.
Remove the following parts in advance.
Left Cover
2.
When any paper is loaded, remove it.
3.
Turn the printer ON.
4.
Start the Service Program and select
CR Belt Tension Check
.
5.
Click
[Run]
.
The CR Unit moves left and right three times, and then moves to the center.
Figure 4-14. [CR Belt Tension Check] Screen