SC-F9200 Series
Revision B
DISASSEMBLY & ASSEMBLY
Disassembly and Assembly Procedure
201
SE Group Confidential (Related Staff Only)
16. Disconnect the CR FFC from the connector (CN100) on the Sub Board.
17. Remove the FFC clamp that secures the Head FFCs.
Figure 3-144. Removing the Ink Path Holder Assy
18. Remove the six screws, and remove the two CR Stopper.
C) Silver M3x8 screw: 6 pcs
19. Remove the screw, and remove the CR Scale Mounting Plate.
D)Silver M3x6 Cup S-tite screw: 1 pcs
Figure 3-145. Removing the CR Stopper
Sub Board
CR FFC
FFC Clamp
CN100
C A U T I O N
Never remove or loosen the screw shown below.
C
C
C A U T I O N
C
C
C
C
D
CR Scale Mounting Plate
CR Stopper
Never remove!
CR Stopper