ADJUSTMENT
Media Feed Related Checks and Adjustments
339
SE Group Confidential (Related Staff Only)
5.
Turn the printer ON.
6.
Start the Service Program and select
PF Belt Tension check
.
7.
Click
[Run]
.
The PF roller rotates 30 revolutions.
Figure 4-61. [PF Belt Tension check] Screen
8.
Input the following information on the belt into the tensimeter.
MASS:
1.3 g/m
WIDTH:
6.0 mm/R
SPAN:
107 mm
9.
Bring the microphone of the tensimeter close to the belt as shown in
.
10. Press the
[MEASURE]
button on the tensimeter, and flip the timing belt with
tweezers or a similar tool.
11. Measure the belt tension three times and check if the average is within the
standards.
Within the standards: Go to
Out of the standards: Go to
12. Click
[Finish]
.
13. Turn the printer OFF to finish the adjustment.
C H E C K
P O I N T
The distance between the microphone and the belt surface should
be 5 mm or less, but do not let it touch the belt.
C A U T I O N
Flip the timing belt as weak as the tensimeter can measure it.
Be careful not to let the microphone touch the timing belt when
flipping the belt.
Summary of Contents for SC-F9200 series
Page 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Page 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Page 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...
Page 389: ...SE Group Confidential Related Staff Only C H A P T E R 6 APPENDIX ...