ADJUSTMENT
CR Related Adjustments
304
SE Group Confidential (Related Staff Only)
4.10.4 CR Scale Check
EXECUTION MODE
Normal Mode
PROCEDURE
1.
Turn the printer ON.
2.
Start the Service Program and select
CR Scale Check
.
3.
Click
[Run]
.
The CR Unit moves left and right four times, and then the CR Encoder starts to
read the scale.
The result is OK: Go to
The result is NG: Go to
Figure 4-23. [CR Scale Check] Screen
4.
Since the CR Scale is not scanned correctly, clean the scale using ethanol. If the
scale still cannot be read properly, replace the CR Encoder
or the CR
Scale
. After replacing the part, return to
to check again.
5.
Click
[Finish]
.
6.
Turn the printer OFF to finish the adjustment.
Figure 4-24. CR Encoder and Scale Check
CR Encoder
CR Scale