SC-F9200 Series
Revision C
TROUBLE SHOOTING
Remedies for Service Call Error
51
SE Group Confidential (Related Staff Only)
151B
APG Motor
over speed error
The APG Motor was driven at a speed faster than a
predetermined one during deceleration.
Irregular load
APG encoder failure
APG Motor driver failure
---
1. Replace the APG Motor.
2. Replace the Main Board.
151C
APG Motor
reversing error
The number of occurrences of reversing the APG
Motor has reached a predetermined limit.
The polarity of APG Motor cable is opposite.
APG Motor failure
Is there any problems such as damaged cable in the
connections below?
APG Motor (APG encoder) to Main Board
(CN210/CN203)
Replace the APG Motor.
151D
APG Motor
driving time-out error
Abnormally-long driving duration of the APG Motor
was detected.
Irregular load
Firmware becomes out of control.
---
151E
APG Motor
velocity deviation error
The APG Motor was driven at a speed abnormally
faster than a predetermined one during acceleration or
deceleration.
Irregular load
APG encoder failure
APG Motor failure
APG Motor driver failure
---
1. Replace the APG Motor.
2. Replace the Main Board.
151F
APG Motor
lock error
Connection failure of the APG Motor.
The APG Motor was driven at a speed abnormally
slower than a predetermined one during operation.
Irregular load
APG encoder failure
APG Motor failure
Is there any problems such as damaged cable in the
connections below?
APG Motor (APG encoder) to Main Board
(CN210/CN203)
Replace the APG Motor.
1599
ATC Motor
oscillation error
The control terminal (Vre terminal) of the ATC Motor
driver has shorted out.
1. Is the ATC Motor driver on the Main Board
damaged?
2. Is there any foreign materials around the ATC
Motor driver?
1. Remove the foreign material.
2. If the error still occurs, replace the Main Board.
Table 2-4. Troubleshooting for Service Call Error
Code
Error Name
Cause
Check Item
Remedy
Summary of Contents for SC-F9200 series
Page 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Page 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Page 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...
Page 389: ...SE Group Confidential Related Staff Only C H A P T E R 6 APPENDIX ...