Ink Supply
related
Main Unit Measurement
& Automatic Adjustment
The Pump Cap Motor is designed to stop when
the amount of heat generation (motor
temperature) during motor operation reaches a
predetermined limit. The amount of heat
generation is estimated based on the electrical
characteristics of the motor, which vary by motor
and power supply of the printer. Therefore, to get
the motor control to work properly, the electrical
characteristics values of the motor need to be
measured and stored in the memory on the Main
Board.
If this adjustment is not made, the estimation of
the motor temperature cannot be made properly
and may cause the following symptoms.
Even though there is no problem with the
motor temperature, the printer pauses during
printing because it judges that the motor is in
high-temperature state.
Despite the motor is in a high-temperature
state, a lower motor temperature is estimated
and the printer does not stop. This may cause
the printer to malfunction.
Normal
mode
√
Switch between Ink
cartridges and Ink tanks
Activates the ink cartridges for service or ink
tanks.
When cartridges or tanks are not recognized
Normal
mode
√
Activation of Cleaning
cartridges
Activates the cleaning cartridges.
When the cleaning cartridges are not recognized
Normal
mode
√
Change flag
(nB <--> HDK)
Switches the mode between high density black
and normal black.
---
Normal
mode
√
Media
Feed
related
PF Belt Tension check
Apply a specified tension to the PF timing belt.
Measure the tension of the belt using the sonic
tensimeter to check if it is within standards. If
not, adjust the tension.
When the belt tension is out of standards, the
following symptoms may occur.
Belt tension is high:
The life of the belt will be shortened. High
load applied to the PF motor causes frequent
wait controls during paper feeding to prevent
overheating. If the tension is too high, the
shaft of the motor leans and the brush in the
motor becomes worn, and will result in PF
motor overload error (112A).
Belt tension is low:
The belt teeth slip and paper cannot be fed
properly.
Normal
mode
√
Tensimeter
U-507
Table 4-2. Adjustment Items
Class
Adjustment Items
Overview
Symptoms that the Adjustment is Needed
Printer Mode
Service
Program
Jig
Media
Page
Summary of Contents for SC-F9200 series
Page 11: ...SE Group Confidential Related Staff Only C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 37: ...SE Group Confidential Related Staff Only C H A P T E R 2 TROUBLESHOOTING ...
Page 76: ...SE Group Confidential Related Staff Only C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 258: ...SE Group Confidential Related Staff Only C H A P T E R 4 ADJUSTMENT ...
Page 365: ...SE Group Confidential Related Staff Only C H A P T E R 5 MAINTENANCE ...
Page 389: ...SE Group Confidential Related Staff Only C H A P T E R 6 APPENDIX ...