2-26
Setup
Rev. C
Confidential
5
Engage the right and left tabs on the IR-320 with the right and left grooves in the back of the
LCD unit. When both sides are engaged, slide the LCD unit down while pressing the lock
lever on the left side of the LCD unit.
6
The LCD unit has a 34-pin connector cable and a 38-pin connector cable. Attach the ferrite
core (an accessory of the IR-320) to the 34-pin connector cable.
7
Connect the cables for the LCD unit to their connectors.
8
Check the Jumper Switch setting. For the DM-LR121SV/DM-LR121SL, set the JP1 to “1-2.”
9
Install the printer unit or the printer tray, and lock it with two screws.
10 Reattach the side cover.
groove in the LCD unit
tab on the IR-320
POS board
CN51
CN31(38-pin)
CN35(34-pin)
JP1
layout of the connectors
Jumper Switch