5-20 BIOS Functions
Rev.C
3) FDD, Error Halt
The items related to the FDD and error that halt at boot-up are as follows.
Notes:
When the
Drive A
is
None
setting, the system resources, such as the IRQ, cannot be released.
Item
Options
Notice
Landing Zone
-----
This item indicates the head fixed track number for the connection
device. The following differences will occur, depending on the device
detection method used.
Auto:
The value obtained by the device is displayed.
Manual: The user can set the value within a range of 0-65,535 only when
the access method is set as “CHS”. (When connecting a
device for which there is no particular value specified, the
number “1” is specified as the maximum number of cylinders).
Sector
-----
This item indicates the number of sectors for the connection device.
The following differences will occur, depending on the device
detection method used.
Auto:
The value obtained by the device is displayed.
Manual: The user can set the value within a range of 0-255 only when
the access method is set as “CHS”.
Item
Options
Fail-Safe Default
Optimized Default
Drive A
None
360K , 5.25 in.
1.2M , 5.25 in.
720K , 3.5 in.
1.44M, 3.5 in.
2.88M, 3.5 in.
None
1.44M, 3.5 in.
Halt On
All Errors
No Errors
All,But Keyboard
All,But Diskette
All,But Disk/Key
All Errors
All Errors
Summary of Contents for IR-320
Page 1: ...Technical Reference Manual IR 320 Issued Date Issued by EPSON English 404368102 ...
Page 2: ......
Page 38: ...1 22 IR 320 System Overview Rev C ...
Page 260: ...4 80 Utilities Rev C ...
Page 294: ...5 34 BIOS Functions Rev C ...
Page 308: ...6 14 Device Diagnostics Utility Rev C Confidential ...
Page 324: ...A 4 Wake On LAN Rev C Confidential ...
Page 332: ...B 8 The IR 310 Compared to the IR 320 Rev C ...
Page 339: ......
Page 340: ...EPSON SEIKO EPSON CORPORATION ...