6-12
Device Diagnostics Utility
Rev. C
Confidential
•
Print test on receipt paper (standard print pattern)
•
Autocutter test (for the autocutter equipped printer only)
When the test is completed, the message
TM print test: done
is displayed in the
message area. Make sure that the print pattern has been printed. For the autocutter
equipped printer, make sure that the receipt paper has been cut by the autocutter.
If the TM status is
Disable
or
No communication
, this test is not executed.
❏
DM display test
Sends the following messages to the DM display.
Display Module Test
**** Device Diagnostics ****
Check the screen of the customer display to make sure that the test has been executed.
When any key is pressed, the test will terminate, and the message
DM display test:
done
is displayed in the message area.
If the DM status is
Disable
or
No communication
, this test is not executed.
❏
Drawer kick-out test
The drawer kick-out test opens the cash drawer. Check to see if the cash drawer opens
normally. The TM printer has two drawer kick-out drive signals (signal 1 and signal 2). This
test checks the drawer kick-out drive signal 1 only.
If a password is set for the drawer kick-out test, enter the password when the drawer
kick-out test is executed.
If the TM status is
Disable
or
No communication
, this test is not executed.
❏
COM1/COM2/COM5/COM6 loop-back
The transmission/reception test for the serial port is executed. Because transmission and
reception are performed through a single target port, the loop-back connector needs to be
connected to the target port. The COM port test checks DTR, DSR, CTS, RTS, TXD, and RXD
signals.
When the test finishes normally,
OK
is displayed in the message area of the screen. When the
test fails, an error message is displayed.
❏
LPT1 loop-back
The LPT1 signal lines are tested. Because transmission and reception are performed through
a single target port, the loop-back connector needs to be connected to the target port. The
LPT1 port test checks STROBE, ACK, DATA0, BUSY, AUTO FEED, PAPER EMPTY, ERR,
INIT, SELECT IN, and SELECT signals. In the loop-back test, the data line test is not
executed. Data line check must be made through the LPT1 print test.
When the test finishes normally,
OK
is displayed in the message area of the screen. When the
test fails, an error message is displayed.
Summary of Contents for IR-320
Page 1: ...Technical Reference Manual IR 320 Issued Date Issued by EPSON English 404368102 ...
Page 2: ......
Page 38: ...1 22 IR 320 System Overview Rev C ...
Page 260: ...4 80 Utilities Rev C ...
Page 294: ...5 34 BIOS Functions Rev C ...
Page 308: ...6 14 Device Diagnostics Utility Rev C Confidential ...
Page 324: ...A 4 Wake On LAN Rev C Confidential ...
Page 332: ...B 8 The IR 310 Compared to the IR 320 Rev C ...
Page 339: ......
Page 340: ...EPSON SEIKO EPSON CORPORATION ...