3-64
OS and Drivers
Rev. C
When operating the right button
This operation sends touch panel coordinate data as mouse right button data.
When operating the left button (normal operation)
This operation sends touch panel coordinate data as mouse left button data.
Touch Panel Driver for MS-DOS
When the LCD panel is changed or the MEDSTD.COM is installed, calibrate the Touch Panel by
using the calibration.
Note:
MEDSTD.COM must load before the calibration.
Follow the procedures below to calibrate.
1. Type the following:
caldstd I10 P2E8 B96 S
The meaning of these parameters are as follows.
Ixx:
IRQ number [Default: 10]
Pxxxx:
Port address [Default: 2E8]
Bxx:
Baudrate [Default: 9600]
S:
Graphic mode [You need parameter S.]
Text mode [You don’t need parameter S.]
2. The calibration screen is displayed, and nine + mark is displayed.
3. Press the + mark in the top left corner of the screen.
4. Touch the nine "+" marks on the screen.
5. When you finish calibration, press SPACE bar to save the calibrated data. Then press any
key to go to drawing test.
6. If you need to stop the calibration, press the "ESC" key to ignore the calibrated data. Then
press any key to go to drawing test.
When in the 1 Tap Mode
When in the Right Fix Mode
When in the 1 Tap Mode
When in the Right Fix Mode
Summary of Contents for IR-320
Page 1: ...Technical Reference Manual IR 320 Issued Date Issued by EPSON English 404368102 ...
Page 2: ......
Page 38: ...1 22 IR 320 System Overview Rev C ...
Page 260: ...4 80 Utilities Rev C ...
Page 294: ...5 34 BIOS Functions Rev C ...
Page 308: ...6 14 Device Diagnostics Utility Rev C Confidential ...
Page 324: ...A 4 Wake On LAN Rev C Confidential ...
Page 332: ...B 8 The IR 310 Compared to the IR 320 Rev C ...
Page 339: ......
Page 340: ...EPSON SEIKO EPSON CORPORATION ...