To flag the error tracks as bad, select Y. You see a list of the
tracks as they are flagged and these messages:
Flagging bad tracks...
Cylinder is 237, head is 2
Press ENTER to return to the menu.
Press
Enter
to return to the Hard Disk Format Menu.
Option 3, Non-destructive Surface Analysis
The Non-destructive surface analysis does not destroy any data,
and you can use it to safely check the condition of your hard
disk drive. However, this test does not flag any bad tracks it
detects.
To start the test, select 3-Non-destructive surface
analysis
from the Hard Disk Format Menu. You see these
messages:
Analyze Hard Disk
<Drive 1:>
Read/Verify check for all tracks...
Current cylinder is nnnn
As the program checks each track, it counts the cylinder
numbers down to zero. When the test is complete, the program
displays a report on the status of the disk, such as the following:
Analysis finished.
Count of tracks flagged bad
=
n
Count of tracks with read, verify errors =
n
Count of good tracks
= nnnn
No read,
verify error was detected.
D-12
Physically Formatting a Hard Disk
Summary of Contents for Equity 386SX PLUS
Page 1: ...m u cl3 0 z E 5 J I 1 al y 8 c 7 5 w ii u l X ...
Page 4: ...EPSON E Q U I T Y 3 8 6 S X User s Guide Y19299100100 ...
Page 20: ...6 Introduction ...
Page 38: ...1 18 Setting Up Your System ...
Page 69: ......
Page 70: ...2 32 Running the Setup Program ...
Page 96: ... 7 R _ ri h 14 3 26 Using the Equity 386SX ...
Page 168: ...5 26 dling Options ...
Page 192: ...B 4 Power on Diagnostics ...
Page 232: ...C 40 Performing System Diagnostics ...
Page 246: ... D 14 Physically Formatting a Hard Disk ...
Page 250: ...E 4 Hard Disk Drive Types ...
Page 282: ...8 I n d e x ...
Page 284: ......